Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine,Health & Beauty,Health & Medical,Emergency & Clinics Apparatuses,Examination Therapy Equipments
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Type:
Examination Therapy Equipments
Model Number:
ECG-1200
Place of Origin:
Hebei, China (Mainland)
Place Of Origin:
Hebei,China
Packaging & Delivery
Packaging Details
1 pc per carton
Delivery Time
soon

Digital Twelve Channel ECG

 

 

Specification:

Input Circuit : Floating; Protection against Defibrillator effect
Lead: Standard 12 leads, Lead change automatically 
Patient Current Leakage:<10 μ A
Input Impedance:≥50 Ω 
Calibrating Voltage: 1mV ±3%
A/D Conversion:12 bit
Display:320×240LCD 
Frequency Response:0.05Hz-150Hz
Time Constant:>3.2seconds
CMRR:>80d>100dB(with filter)
Paper Speed:25,50mm/s±3%
Recording Paper: 210mm×30m, high-speed roll
Input Circuit Current: ≤50nA
Safety Standard: IEC class I, type CF
Sensitivity: 1/2,1,2(cm/mV)
Skin Voltage Tolerance: ±300mV
Noise Level:<15 μVp-p
Weight: 5.1kg
Feature:
Simultaneous 12 leads acquisition and printing 
Automatic measurement and interpretation-R analysis
12 leads simultaneous display on large backlight LCD 320×240
Digital design and filter ;Thermal array printer 
Recording on A4 size paper 
Baseline auto-adjustable; Rhythm lead selectable 
DC/AC autoexchange,built-in rechargeable battery. Power supports continuously working for more than 50 patients
16 pieces of unzipped ECG date and waveforms are stored for copy and re-call
Inner handhold designed for portability

Portable ECG manager with the development of electronic, communicative and software technique, It has significant meaning for the early-stage prediction for cardiovascular disease and family medical health care, It has great promotion on size, power consumption, and data storage and data transmision, property and quality, It is great influence on the life security of the patients.

 

 

 

ECG manager use analog low-pass and analog high-pass analog filter just like components band-pass to filter out signal interference, while the use of active notch filter frequency of 50Hz can further filt out interference, getting a more pure ECG signal. And then through the implementation of A/D conversion, single-chip processing system, the final test results will be displayed by LCD. The ECG analyzer has good characteristics such as low-power, portable and real-time and so on.

 

Feature:

1. For the cardiovascular disease testing

2. Use for family medical health care

3. Portable and automatic analysis

4. Precise dataflow analysis and persistent record

 

 

Features: 3301G (single channel)
1. Compact in size, easy and direct operation, portable
2. Accurate pace pulse identification and automatic analysis function
3. Four working modes: Manual / Auto / Physical Examination / Storage
4. 12 leads simultaneous waveforms display
5. 50mm, single channel format recording
6. Advanced [Freeze] function
7. 5" 800x480 graphic 5 inch color LCD
8. Built-in USB, RS232 interface, ECGNET software optional
9. Built-in rechargeable Li-MH battery
10. 250 patient information storage (Exendable)
11. USB interface allows net transmission
12. USB flash disk and USB printer connected
 
Specification:
Lead: Standard 12 leads
Lead acquisition: 12bit/1000Hz(synchronously 12 leads)
Work mode: Manual / Auto / Physical Examination / Storage
Filter:
AC Filter:50Hz/60Hz
EMG Filter: 25Hz/45Hz
Auti-Drift Filter: 0.15Hz (Adaptive)
CMMR:100dB(with AC FILTER)
Input circuit: Floating; Protection circuit against Defibrillator effect
Input Impedance:50MΩ
Input circuit current:0.05μA
Patient current leakage: <10μA
Calibrating voltage: 1mV±2%
Voltage tolerance: ±500mV
Time constant: 3.2s
Frequency response: 0.05~160Hz(-3dp)
Noise level: <15u Vp-p
Inter-channel Interference: 0.5mm
Sensitivity: Auto, 2.5,5,10,20,40mm/mV
Recording mode: 
1ch,1ch+
Default Man. Mode is 1ch format
Default Auto. Mode is 1ch+ format
Paper speed: 6.25, 12.5,25,50mm/s(±3%)
Paper: 50mm Roll Paper
Communication: RS232/USB port
Power supply: AC 110-230V(±10%),50/60Hz(±1Hz), 30VA
DC Built-in rechargeable battery, 12V(1500mAh)
Dimension/Weight: 330x270x75mm/2.8kg

 

Product Details: Structure & Function

 

1. Front Panel and LCD

 Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

  (1) Handle (2) Paper Switch (3) Paper Cover (4) LCD (5) Keypad

 

 

2. Control Keypad Panel

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine 

 

  Symbols on the device body:

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

 

3. BottomPanel and Lateral Panel

 Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

Patient Cable Interface

 

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine 

 
Analog I/O and UART Interface (RJ11) :Used for
* Record analog External Input In [TEST] lead of [MAN] mode.
* Export the Rhythm Lead of the [BASIC] menu to Analog External Output.
* Communicate with personal computer for 12 lead real-time ECG transmission and ECG
files transmission.(Needs optional ECG Archive Software and UART/USB cable).

 

 Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

 

USB/Host Interface (Optional) :Used for

Transmit ECG file to ECG Archive software based on personal computer, Please refer to the ECG Software Operation Manual for more information.
* Save ECG files to a external USB disk via USB/Host interface; the files can be imported into ECG Archive software, Please refer to the User Manual for more information.
* Print ECG report to a external USB printer(PCL command) via USB/Host interface; details about the supported USB printer, please contact our service department.
CAUTION:The USB cable should be well shielded and can not be longer over 3 meters, It's better to use the manufacturer's recommended USB cable.

 

USB or LAN Interface (USB/RJ45,Optional) :Used for
* Communicate with personal computer system(This need a optional ECG Archive software, Please refer to the ECG Software Operation Manual for more information).
CAUTION:The USB or LAN cable should be well shielded and can not be longer over 3 meters, It's better to use the manufacturer's recommended USB cable.

 

 

4. Connecting Electrodes(as following)

 

The identifier and color code of electrodes used comply with IEC requirements. In order to avoid
incorrect connections, the electrode identifier and color code are specified in below Table. The
equivalent code of American standard is given too.

 

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

The Limb/Chest electrode should be placed on body surface shown as following:

 

V1 : Fourth inter-costal space at right border of sternum.
V2 : Fourth inter-costal space at left border of sternum.
V3 : Fifth rib between V2 and V4.
V4 : Fifth inter-costal space at left mid-clavicular line.
V5 : Left anterior axillary line at the horizontal lever of V4.
V6 : Left anterior mid-axillary line at the horizontal lever of V4.

 

 

 

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

NOTE : Tangling of electrodes or overlap from one place to another of ECG creamis not allowed.

 

 

5. ECG Explanation on measurement

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

 

6. ECGNET (sell in addition)

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

Package: 1pc / inner box , 4pcs / carton

Electrocardiograph Analyser New Digital Twelve Channel ECG Machine

 

 

Factory:

1. Quality first spirit

2. Professional service team

3. Convenient transport

4. Certificate: Medical CE

 

 

Company profile:

Chongqing Joywell Trade Co.,Ltd.  has been in Chongqing China in 1999, It has a professional team to engage at international business and a long-term cooperated factories as powerful backing.

 

Qulity spirit, wonderful service and team work are always the first. Through develop more than 10 years, we have lifted up a new stage and established a wide customer group which from United States, United Kingdom, Cannada, Germany, Japan, South Korea, Iran, New Zealand, Qatar, Irealand, Spain, Netherland, Chile, etc.

 

The team cooperation open up and share innovation.

AIM: Employee's success is the success of the company.

VALUE: Intergrity first, customer first, cooperation sharing, happy passion, refince on active, thanksgiving growth.

MISSION: Let customer satisfaction, let the Joywell products are well-known in the world.

VISION: To meet the challenge, success!

 

We would like cooperate with clients from all over the world.

 

Electrocardiograph Analyser New Digital Twelve Channel ECG MachineElectrocardiograph Analyser New Digital Twelve Channel ECG MachineElectrocardiograph Analyser New Digital Twelve Channel ECG Machine