Latest Accurate Spacelab Patient Monitor With Uninterrupted Monitoring

Latest Accurate Spacelab Patient Monitor With Uninterrupted Monitoring

Latest Accurate Spacelab Patient Monitor With Uninterrupted Monitoring,Contec,Health & Beauty,Health & Medical,Emergency & Clinics Apparatuses,Examination Therapy Equipments
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Type:
Examination Therapy Equipments
Brand Name:
Contec
Model Number:
CMS7000
Place of Origin:
Hebei, China (Mainland)
ECG Lead Mode:
3-lead and 5-lead are optional
ECG Lead Selection:
I, II, III, avR, avL, avF, V
ecg Wave 5-lead:
2 channels
CMRR Monitor:
≥ 100 dB
NIBP Method:
Oscillometry
NIBP Mode:
Manual, Auto, continuous
NIBP Measuring Period:
in Continuous Mode 5 Min
SpO2 Measuring Range:
0 ~ 100 %
TEMP Channel:
Dual-Channel
Dimension:
310*140*263(mm)
Packaging & Delivery
Packaging Details
in carton
Delivery Time
Less than 100sets;about10days;more than 100sets:about15days

Specifications

1. High-quality Spacelab Patient Monitor
2. Lightweight,compact and portable
3. Built-in rechargeable lithium battery

Product Name:         

 

                   Latest Accurate Spacelab Patient Monitor With Uninterrupted Monitoring  

 

Introduction:

 

This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a compact and portable device. At the same time, its built-in replaceable battery provides convenience for patient moving.

 

Detailed picture:

 

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

Major Features:

 

1. Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.

 

2. Be applicable for adult, pediatric and neonatal.

 

3. Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.

 

4. Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance.

 

5. 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously.

 

6. Monitoring contents, scan speed, volume and output contents can be set optionally.

 

7. Storage of 480-hour trend data, and review of 40-second holographic waveform.

 

8. Storage and review of 72-hour ECG waveform.

 

9. Function of NIBP review, storage for up to 2400 NIBP data.

 

10. Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

 

11. Calculation of drug concentration.

 

12. Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.

 

13. Built-in rechargeable battery for uninterrupted monitoring.

 

14. Print ECG, SpO2, RESP, BP and temperature data with one-key.

 

15. Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

 

16. Analysis function for heart rate variability(HRV) (optional)

 

17. Power supply: 220 V, 50 Hz

 

18. Dimension: 310*140*263(mm)

 

19. Net weight: 3.8 Kg

 

Major Performance:

 

ECG:

 

1. Lead Mode 3-lead and 5-lead are optional

 

2. Lead Selection I, II, III, avR, avL, avF, V

 

3. Wave 5-lead: 2 channels

 

4. 3-lead: 1channel

 

5. Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV

 

6. HR Measuring and Alarm Range

 

7. Range 15 ~ 300 bpm

 

8. Accuracy ±1% or ±1bpm, which is greater

 

9. Alarm Accuracy ±2bpm

 

10. Resolution 1 bpm

 

11. Monitor(CMRR) ≥ 100 dB

 

12. Surgery(CMRR) ≥ 100 dB

 

13. Diagnosis(CMRR) ≥ 60 dB

 

14. Surgery(bandwidth): 1 ~ 20 Hz(+0.4dB,-3dB)

 

15. Monitor(bandwidth):  0.5 ~ 40 Hz(+0.4dB,-3dB)

 

16. Diagnosis(bandwidth): 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB)

 

17. ST Segment Monitoring Measuring and Alarm Range: -0.6 mV~ + 0.8 mV

 

18. ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

 

19. Alarm Available

 

20. Review Available

 

21. Scan Speed for ECG Waveform is adjustable:

 

     12.5mm/s accuracy ±10%

 

     25mm/s accuracy±10%

 

     50mm/s accuracy±10%

 

 

Respiration:

 

 

1. Method R-F(RA-LL) Impedance

 

2. Differential Input Impedance >2.5 MΩ

 

3. Measuring Impedance Range 0.3~5.0Ω

 

4. Baseline Impedance Range 100Ω– 2500Ω

 

5. Bandwidth 0.3 ~ 2.5 Hz

 

6. Measuring and Alarm Range 0~120rpm

 

7. Resolution 1 rpm

 

8. Measuring Accuracy ±2 rpm

 

9. Alarm Accuracy ±3rpm

 

10. Apnea Alarm 10 ~ 40 S

 

NIBP:

 

1. Method: Oscillometry

 

2. Mode: Manual, Auto, continuous

 

3. Measuring Interval in AUTO Mode: 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min

 

4. Measuring Period: in Continuous Mode 5 Min

 

5. Measuring and Alarm Range: 10~270mmHg

 

6. Alarm Type: SYS, DIA, MEAN

 

7. Resolution:

                      Pressure: 1mmHg

                      Cuff Pressure: ±3 mmHg

                      Accuracy: ±10% or ±8mmHg, which is greater

 

8. Over-pressure Protection:

                      Adult Mode: 315±10 mmHg

                      Pediatric Mode: 265±10 mmHg

                      Neonatal Mode: 155±10 mmHg

 

SpO2:

 

1. Measuring Range 0 ~ 100 %

 

2. Alarm Range 0 ~ 100 %

 

3. Resolution 1 %

 

4. Accuracy:

                      70% ~ 100% ±2%

 

                      0% ~ 69% unspecified

 

5. Pulse rate:

                      Measuring and Alarm Range 0~250bpm

                      Resolution 1bpm

                      Measuring Accuracy ±2bpm or ±2%, which is greater

                      Alarm Accuracy ±2bpm

 

TEMP:

 

1. Channel: dual-channel

 

2. Measuring and Alarm Range: 0 ~ 50°C

 

3. Resolution: 0.1°C

 

4. Accuracy: ±0.1°C

 

5. Actualization Interval: about 1 Sec.

 

6. Average Time Constant: < 10 Sec.

 

7. Alarm responding Time: ≤2min

 

EtCO2:

 

1. Method: Sidestream or Mainstream

 

2. Measuring Range for CO2: 0~150mmHg

 

3. Resolution for CO2:

                       0.1 mm Hg 0 to 69 mm Hg
                       0.25 mm Hg 70 to 150 mm Hg

4. Accuracy for CO2:

                       0 – 40 mm Hg ±2 mm Hg
                       41 – 70 mm Hg ±5%
                       71 – 100 mm Hg ±8%
                      101 – 150 mm Hg ±10%

 

5. Respiration Rate:>80BPM ±12%

 

6. AwRR Range: 2~150 rpm

 

7. AwRR Accuracy: ±1BPM

 

8. Apnea Alarm Available

 

IBP:

 

1. Channel: dual-channel

 

2. Labe:l ART, PA, CVP, RAP, LAP, ICP, P1, P2

 

3. Measuring and Alarm Range: -50~350 mm Hg

 

4. Resolution: 1 mm Hg

 

5. Accuracy: ±2% or 1mm Hg, which is greater

 

Accessories:

 

1. Adult SpO2 probe(5-pin)

 

2. Adult NIBP cuff

 

3. Extending tube for blood pressure

 

4. ECG lead

 

5. ECG electrode

 

6. Temperature probe

 

7. Power cord

 

8. Thermal recording paper(optional)

 

9. User Manual

 

Certification:

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

Latest Accurate Spacelab Patient Mo<em></em>nitor With Uninterrupted Monitoring

 

 

 

 

-------------------------------------------------------------------------------

 

 

 

Fine quality is our promise

 

 

 

Considerate service is our responsibility

 

 

 

Passing on health is our wish

 

 

 

Your satisfaction is our pursuit